.:: Control & Safety Relays ::.
   
 
 
Application and Operation Principles

FL-2R : Once the supply voltage is applied. 
The relay is switched on within  "ton " time period. 
At the end of  " ton " period the relay switches off 
and keeps the position within " toff " period. 
At the end of " toff " period the relay switches on again.   
  
FL-R :
Is delay-time adjustable [(t) 0.1-12 sn.] In between two impulses. The relay is switched off when the supply voltage is applied and keeps the position within “t” time period. At the end of “t” time period the relay switches on and waits for 0.5 second. After the end of 0.5 second the relay switches off again.
FL-RT: FL-RT has a triac output in comparison with FL-R. FL-V2R : FL-V2R is used to operate and pause the machines in certain period of times or upon the request of the proposed time periods. Once the voltage supply is applied the relay is switched on. The relay switches off when “ton” time period ends. The relay is inactive until the “toff” time period ends and the relay switches on and keeps counting as much as “ton” time duration. FL-V2R is used in oiling systems, signalisations, signal lamps, incubation machines, etc. SX-2R : Designed to use for a purpose to inverse the direction of rotating machines in industrial automation systems. Once the supply voltage is applied Left-relay is switched on after 6 second then is switched off at the end of the adjusted time period. It waits for 6 second upon which the right-relay is to be switched on. The relay switches off at the end of the adjusted time and waits for 6 second in order to have the left-relay switched on. It repeats the function systematically. Technical data for FL-2R
Supply Voltage : 220-240V AC 50-60Hz 24V AC-DC • Setting Error :+5%
• Contact Output : 220 VAC-5A
• Operation temperature : -40C ... +55C • Net Weight : 150 gr

Technical data for FL-R

• Supply Voltage : 220-240 V AC 50-60 Hz
• Sensitivity : +0.1%
• Contact Output : 250 V AC - 5A
• Operation Temperature : -40C ... +55C
• Net Weight :125 gr

Technical data for FL-V2R

• Supply Voltage : 220-240 V AC 50-60 Hz
                             24 V AC - DC
• Sensitivity : +0.1%
• Contact Output : 250 V AC - 5A
• Operation Temperature : -40C ... +55C
• Net Weight :75 gr

Technical data for SX-2R

• Supply Voltage : 220-240 V AC 50-60 Hz
• Sensitivity : +0.1%
• Contact Output : 250 V AC - 5A
• Operation Temperature : -40C ... +55C
• Net Weight :125 gr

                      Connection Diagram for Slim Type
             Dimensions              
                     Connection Diagram for Classic Type
 Dimensions
details
PDF for FL-2R
details
PDF for FL-R
details
PDF for FL-V2R
details  
PDF for SX-2R
 
.:: Ordering Information :::..
Order No 
Technical Description 
Dimensions((mm) 
Weight(gr) 
**** Special Time Controllers ****
RY-2R
0,1-12 Sec.Adjustable Star-Triangle Relay
45x75x107
125
RY-V2R
Slim Type 0,1-12 Sec.Adjustable Star-Triangle Relay
23x75x90
75
RG-06
0,1-06 Sec. Adjustable Power-Off Triggeret Off Delay
45x75x107
300
ST-R
Start-Stop Relay
45x75x107
250
PKR-24
Press Button Safety Relay
45x75x107
125
AC-DC
12V AC/12V DC Adaptor
45x75x107
125
AC-DC
220V AC /12V DC Adaptor
45x75x107
240
**** Flashers ****
FL-R
0,1-12 Sec. Single Adjustable (Blink)
45x75x107
125
FL-RT
0,1-12 Sec. Single Adjustable Output Triac (Blink)
45x75x107
125
FL-2R
2-60 Sec./2-60 Min. Double Adjustable
45x75x107
150
FL-V2R
Slim Type 2-60 Sec./2-60 Mim.Double Adjustable
23x75x90
75
**** Inversor (Left-Right) Relays ****
SX-2R 2-60 Sec. Adjustable
45x75x107
125
SX-2RT 2-60 Sec. /2-60 Sec. Double Adjustable
45x75x107
250
SX-4RT 4 Independent Time Adjustable
45x75x107
300