Application
and Operation Principles
MKR-03
: Industrial type Monophase Motor Protection relays are required
to operate at a certain voltage ranges in order to reach productivity
and not to get damaged for that reason. Unsettled voltage ranges and fluctuations
above the set limits may cause inconveniences and damages. MKR-03 is specially
designed to overcome such problems on motor. Switching on adjustability
at low voltage ranges (140-200= makes the relay switches on and the LED
is on if the supply voltage is in between the set values and then motor
starts. The relay switches off and the LED is off when the voltage is
below the set values or exceeds 240V and then motor stops. Motor will
restart provided that the supply voltage reaches at the set values.
NOTES : MKR-03 is the best-used
for the monophase motor being under the negative effect of low/high voltages
No auxiliary contact is requared under 1KW
MSR-0X
: MSR-0X is used to sequence motors in row of regular order in
following to switching the pressures (P1, P2, P3) buttons on. Motor operating
priority is allocated by the relay due to which motor was switched off
the earliest disregarding of pressure(P1, P2, P3) switching on order.
In case of the need, other motors are to be switched on the operation
in due order of the motor -break.
Main purpose to use MSR-0X type relays is to extend the motor life by
means of the above said operating functions.
Technical
datas for
MKR-03
• Supply Voltage : 220-240V AC 50-60Hz
• Contact Output : 250VAC-5A
• Unbalance Protection : +15%
• Under Voltage : 140V-200V(Adjustable)
• Over Voltage : 240V
• Hysteresis : max. 15V
• Adjustable sensivity : +5 V
• Operation Temperature : -40C ... +55C
• Net Weight : 250 gr
Technical
datas for
MSR-0X
• Supply
Voltage : 220-240 V AC 50-60 Hz
• Contact Voltage : 250 V - 5A
• Operation Temperature : -40C ... +55C
• Net Weight : 300 gr
|