| Application
and Operation Principles
R1 - DAXX,
R2 - DAXX and R3 - DAXX are used to precisely measure and monitoring the
RMS, value of AC current in between two set points. Possession of 10-1500
A measuring range make RX-DA electronic ammeters the most demanded for
different purpose of applications. RX-DA are being commonly used in the
panel boards of which provide an extensive control of high current flowing
system.
R1-DA-XX : The current value is displayed once the meter
is energized. R1-DAXX types must be carefully selected according to the
use of current transformer.
R2-DA-XX : Current Transform Ratio (Primer current value)
is adjustable via dip switch built on the back.
R3-DA-XX : Up to 50 A without current transformer, the
current is directly measured.
Technical
datas
• Supply
Voltage : 220-240 V AC 50Hz-60 Hz
• Measurement Interval : 10...1500/5 A
• Measurement Sensitivity : + 2%
• Operation Temperature : -40C ... +55C
• Net Weight : 348 gr (96x96), 346 gr (72x72)
NOTE
: Upon request, the ammeter with different voltages supplies
can be produced. |